Performance of Windposts to Eurocode 3

Performance of Windposts to Eurocode 3

Design Resistance (kN) per Post (uniformly distributed) for Various Windpost Spans

Height 2.1 m 2.3 m 2.5 m 2.7 m 2.9 m 3 m 3.2 m 3.4 m 3.6 m 3.8 m 4 m
Standard wind post
80×80×6 SHS S355 13.61 14.90 16.20 14.54 12.53 11.79 10.37 9.18 8.15 7.35 6.60
90×90×6.3 SHS S355 13.61 14.90 16.20 17.50 18.42 17.33 15.24 13.49 11.99 10.81 9.70
-special order
90×90×8 SHS S355 13.61 14.90 16.20 17.50 18.79 19.44 17.94 15.88 14.11 12.72 11.42
100×100×10 SHS S355 13.61 14.90 16.20 17.50 18.79 19.44 20.74 22.03 23.24 20.96 18.81

Note: Table based on tie spacing of 225mm. Figures in bold indicate capacity limited by tie capacity.

Windposts are designed as ‘simply supported beams’ with a maximum deflection of span/360.

Maximum design loads to BS EN 1993 (Eurocode 3). The design resistances shown should be compared to factored loads.

Windposts comply with all CE marking requirements of BS EN 1090-1, including designs to EN 1993 (Eurocode 3) and external certification of our factory production controls by an approved body.